LOGGING UNITS



  • 9065 LoGging Tool

    The 9065 tool is three-arm caliper configuration used to measure the diameter of the borehole. It can be used in both open and cased holes.

    MAKE AND MODEL

    CENTURY

    FEATURES

    PROPERTIES MEASURED

    Three-arm caliper:
    Short - or long – arm configuration, Motor operated

    Offset:
    Short-arm: 156 cm (61.5in.)
    Long-arm: 195.37 cm (76.92 in.)
    Extra-long-arm: 241.1 cm (94.92 in.)

    TOOL SPECIFICATIONS

    Length:
    Short-arm: 178 cm (64 in.)
    Long-arm: 203.2 cm (80 in.)
    Extra-long-arm: 5,201.92 cm (96 in.)

    Temperature:
    60 C (140F)

    Diameter:
    4.3 cm (1.7 in.)

    Pressure:
    232 kg/cm2 (4000 psi)

    Weight:
    Short-arm: 7.7 kg (20 lbs.)
    Long-arm: 9.24 kg (24 lbs.)
    Extra-long-arm: 10.87 kg (28 lbs.)
    Logging Speed: 9 m/min.(30ft./min.)

    SENSOR RESPONSE RANGES:

    SENSOR
    Short-Arm Caliper
    Long-Arm-Caliper
    Extra-Long Arm Caliper

    RESPONSE LIMITS
    5.1-50.8 cm (2-20in.)
    10.1-101.6 cm (4-40 in.)
    10.1-182.88 cm (4-72 in.)

    ACCURACY
    +/-0.38 cm (0.15 in.)
    +/-0.64 cm (0.25 in.)
    +/-1.28 cm (0.50 in.)

  • 9043 LOGGING TOOL

    The 9043 tool is a multi-parameter resistivity tool primarily used for Water & Oil well logging and monitoring wells. The tool records nine different parameters simultaneously in one pass of the borehole. The nine parameters are the following: natural gamma, spontaneous potential, single point resistance. 16 in. normal resistivity, 48 in. lateral resistivity, fluid resistivity, temperatures, and differential temperature.

    MAKE AND MODEL

    CENTURY

    FEATURES

    PROPERTIES MEASURED

    Natural Gamma:
    2.5 x 4.6 cm (1.0 x 1.8 in.) NAI Scintillation
    Offset: 13.5 cm (5.3 in.)

    64 in. Normal:
    Offset: 110.5 cm (43.5 in.)

    16 in. Normal:
    Offset: 171.5 cm (67.5 in.)

    Fluid Resistivity:
    Offset: 229.9 cm (90.5 in.)

    Lateral Resistivity 48 in.
    Offset: 109.6 cm (43.1 in.)

    Spontaneous Potential:
    +/- 0.1 mv resolution
    Offset: 27.4 cm (10.8 in.)

    Single Point Resistance:
    +/- 0.1 ohm resolution
    Offset: 191.8 cm (75.5 in.)

    Temperature/Delta
    Temperature: 0.04 C(0.1 F) resolution
    Offset: 237.5 cm (93.5 in.)

    TOOL SPECIFICATIONS

    Length:
    244 cm (96 in.)

    Temperature:
    80 C (176 F)

    Diameter:
    5.3 cm (2.1 in.)

    Pressure:
    183 kg/cm2 (2500psi)

    Weight:
    14 kg (31 lb)

    Logging Speed:
    9 m/min. (30ft/min.)

    SENSOR RESPONSE RANGES

     

    SENSOR

    Natural Gamma

    16. & 64. Normal &
    Lateral Resistivity

    Spontaneous Potential

    Temperature

    Fluid Resistivity

    Single Point Resistance

    RESPONSE LIMITS

    0-400,000 API units


    0-2,000 ohm/meters

    .400-+400mv

    0 C- 70 C (32 – 160 F)

    0-100 ohm meters

    0-2000 ohms

    ACCURACY

    +/-5%


    +/-5%

    +/-5%

    +/-5%

    +/-5%

    +/-5%